A distributor checklist for the SY08-01 intragastric balloon: kit contents, 400–700 mL fill, 6-month maximum stay, and RFQ fields. No outcome claims.
Suzhou Shenyun Medical Equipment Co., Ltd. manufactures the intragastric balloon in its own factory in Suzhou, in a 4,000 m² facility that includes a Class 100,000 cleanroom, and exports to 50+ countries and regions. This checklist is for distributors and hospital procurement teams who need to copy specification fields into an RFQ or a tender annex. It is not a clinical guideline, and it does not discuss who should receive a balloon or what result to expect. Intended use, contraindications and warnings are in the current Instructions for Use and must be read there. Broader sourcing-guide pages already on the site (9002 and 9009) are not repeated here. Types of balloon (liquid, gas, swallowable) are covered in article 10040.
What the current datasheet lists
The Intragastric Balloon datasheet and the technical data sheet describe a non-adjustable medical-grade silicone balloon, model SY08-01, placed and removed endoscopically.
Published specification fields:
| Field | Value in the current datasheet / TDS | |---|---| | Model | SY08-01 | | Material | Medical-grade silicone | | Fill volume | 400–700 mL saline, with methylene blue | | Maximum indwelling period | 6 months; the balloon must be removed (it can be replaced, according to the datasheet) | | Probe diameter | 6 ± 0.2 mm | | Sterility | Sterile, single use |
Kit contents, as published: balloon with check valve; silicone placement probe with sheath; steel guide wire; filling tube; 100 mL syringe.
Placement and removal, as published: the balloon is placed under endoscopic guidance by a qualified endoscopist in an operating room or endoscopy suite. Removal is endoscopic: the balloon is punctured to deflate and then retrieved with grasping forceps. The datasheet states that the device is supplied to distributors, hospitals and bariatric centres, not to individuals.
The six-month maximum is a published use limit, not a performance claim. A request for quotation should point buyers to the current IFU for the full list of contraindications, warnings and potential complications.
Fields to copy into an RFQ or tender annex
1. Product: intragastric balloon, model SY08-01, non-adjustable, medical-grade silicone. 2. Fill volume range: 400–700 mL saline with methylene blue. 3. Maximum indwelling period: 6 months, with removal required; ask whether replacement is part of the account’s protocol (the datasheet says the balloon can be replaced). 4. Kit list: balloon with check valve, placement probe with sheath, steel guide wire, filling tube, 100 mL syringe — and whether any item is also sold separately. 5. Probe diameter: 6 ± 0.2 mm, if the file asks for it. 6. Route: endoscopic placement and endoscopic removal, as described in the IFU. 7. Documents to request: current datasheet, technical data sheet, IFU (including the language needed for the destination market), packaging specification, and the product page. 8. Quantity of complete kits, not only a total balloon count, if the syringe and probe are part of the kit. 9. Label language and packing unit. Do not copy outdated commercial footnotes from older leaflets; use the current packaging specification.
If a hospital file asks for “intended patient groups” or body-mass figures, answer from the current IFU only, or state that the IFU will be attached. This article does not reproduce those statements.
Shenyun Medical can provide specifications and a quotation from the factory in Suzhou. Use the contact form and name model SY08-01 and the destination market.
Sources: - Intragastric Balloon datasheet and TDS (SY08-01 kit and specification fields) - Live product page - Guide 9002 - Guide 9009 - Article 10040