Catheter Series

Medical Silicone Tubing Manufacturer for Distributors

Shenyun Medical is a medical device manufacturer in Suzhou, China, with a 4,000 m² production area and a Class 100,000 cleanroom. We manufacture platinum-cured medical-grade silicone tubing (MST-001 – MST-031; ID 0.5–12 mm, OD 1.3–18.5 mm, 70 Shore A; for connecting medical equipment and laboratory use, not for delivering fluids into or draining fluids from the body) in our own factory and supply distributors, importers and hospital procurement teams; our products are exported to 50+ countries and regions. Specifications, product documents (datasheet and IFU) and quotations are available on request.

Models
MST-001 – MST-031
Inner diameter
0.5–12 mm
Outer diameter
1.3–18.5 mm
Hardness
70 Shore A
Material
Platinum-cured silicone
Use
Equipment connection, lab use
Medical Grade Silicone Tube

Specifications

REFID (mm)OD (mm)Hardness
MST-0010.51.370 Shore A
MST-0032.04.070 Shore A
MST-0073.05.070 Shore A
MST-0094.06.070 Shore A
MST-0125.08.070 Shore A
MST-0156.08.070 Shore A
MST-0217.010.070 Shore A
MST-0268.012.070 Shore A
MST-03112.018.570 Shore A

Product Information

Platinum-cured medical-grade silicone tubing (MST-001–031, ID 0.5–12 mm, OD 1.3–18.5 mm) for connecting medical equipment and lab use; not for delivering fluids into or draining the body.
Medical Grade Silicone Tube

Features

70 Shore A hardness

Platinum-cured medical-grade silicone

31 ID/OD sizes (MST-001–031)

Indications & Contraindications

Indications

  • Non-invasive medical applications in hospitals and similar settings, such as connecting medical equipment, and laboratory use. Not intended for delivering fluids into, or draining fluids from, the human body.
  • Intended users: healthcare and laboratory professionals, and manufacturers using the tubing as a component.
  • Intended environment: hospitals, laboratories and production facilities.

Contraindications

  • Do not use for delivering fluids into, or draining fluids from, the human body.

How to Use

  1. 1Select the tubing size (ID and OD) for the connectors to be used.
  2. 2Cut to the required length with clean tools.
  3. 3Push the tubing fully onto the connectors and check that all connections are secure and free of kinks.

Summary from the Instructions for Use. Use by qualified personnel according to the full Instructions for Use.

Warnings & Storage

Warnings and precautions

  • Check the tubing for damage, contamination or foreign matter before use; do not use if defective.
  • Use clean tools to cut the tubing to length; avoid sharp edges that may damage the tube.
  • Avoid strong oxidising agents and organic solvents, which may cause swelling or damage.
  • Where sterilization or disinfection is required, the user is responsible for validating the process for the intended application.

Storage, transport and disposal

  • Store in the original packaging in a clean, dry place away from direct sunlight, ignition sources and strong oxidising agents.
  • Dispose of according to local regulations; tubing contaminated by use should be treated as clinical waste.

Packaging

Medical Grade Silicone Tube Unit package
Unit package
Medical Grade Silicone Tube Outer carton
Outer carton
LevelDescriptionQuantityDimensions
Unit packagePE zip bag with product label1 coil—
Outer cartonCorrugated carton—56 × 56 × 45 cm
Carton volume0.141 m³

Packaging images are for reference only.

FAQ