Suction Tube Series

Negative Pressure Drainage Set Manufacturer for Distributors

Shenyun Medical is a medical device manufacturer in Suzhou, China, with a 4,000 m² production area and a Class 100,000 cleanroom. We manufacture the closed negative pressure wound drainage set (silicone drainage tube 8–24 Fr, guide needle, 100/200 mL vacuum bulb with anti-reflux valve, optional drainage bag; Type I–IV) in our own factory and supply distributors, importers and hospital procurement teams; our products are exported to 50+ countries and regions. Specifications, product documents (datasheet and IFU) and quotations are available on request.

Types
Type I–IV
Drainage tube
8–24 Fr
Vacuum bulb
100 / 200 mL
Material
Medical-grade silicone / PVC
Supply
Sterile (EO), single use
Packing
48 sets per carton
Sterile Single Use Negative Pressure Drainage Set

Specifications

ModelConfiguration
Type IDrainage tube + Connector + Vacuum suction ball
Type IIDrainage tube + Guide needle
Type IIIDrainage tube + Connector + Guide needle + Vacuum suction ball
Type IVDrainage tube + Connector + Guide needle + Vacuum suction ball + Drainage bag

Product Information

Closed wound drainage set: silicone drainage tube (8–24 Fr), guide needle, 100/200 mL vacuum bulb with anti-reflux valve and optional drainage bag, in Type I–IV. Sterile (EO), single use.
Sterile Single Use Negative Pressure Drainage Set

Structure & Components

Sterile Single Use Negative Pressure Drainage Set Drainage Tube
1Drainage Tube
Sterile Single Use Negative Pressure Drainage Set Guide Needle
2Guide Needle
Sterile Single Use Negative Pressure Drainage Set Drainage Bulb
3Drainage Bulb
Sterile Single Use Negative Pressure Drainage Set Drainage Bag
4Drainage Bag
1

Sterile drainage catheter, optional connectors, guide needle, negative-pressure reservoir (bulb) and, for Type IV, a collection bag. Materials: medical-grade silicone or PVC.

Features

Sterile (EO), single use

Multi-perforated silicone drainage tube, 8–24 Fr

Medical-grade silicone or PVC components

100/200 mL vacuum bulb with anti-reflux valve

Indications & Contraindications

Indications

  • To drain body fluids (e.g. blood, serous fluid) from superficial wounds or surgical incisions in a closed, sterile system.
  • Intended user: trained healthcare providers.
  • Intended environment: hospitals and surgical facilities.

Contraindications

  • Known allergy to silicone or PVC materials.

How to Use

Pre-use inspection

  1. 1Verify packaging integrity and the sterilization indicator.
  2. 2Confirm that the product is within its 3-year shelf life.

Catheter placement

  1. 1Perform hand hygiene and don sterile gloves.
  2. 2Attach the guide needle assembly to the catheter.
  3. 3Under aseptic conditions, puncture the target site and advance the catheter to the desired depth.
  4. 4Withdraw the guide needle, leaving the catheter in place.

System assembly

  1. 1Select the matching connector and secure it to the catheter hub.
  2. 2Attach the reservoir to the connector and squeeze it fully to create vacuum.
  3. 3Open the valve to start drainage.
  4. 4Transition to collection bag (Type III and IV)
  5. 5When the reservoir is full or continuous drainage is required, empty or collapse the reservoir.
  6. 6Connect the collection bag inlet to the connector valve outlet.
  7. 7Hang the bag below the insertion site to maintain gravity drainage.

Removal

  1. 1Clamp the catheter near the insertion site.
  2. 2Disconnect all tubing and remove the adhesive anchor.
  3. 3Withdraw the catheter gently and apply a sterile dressing.
  4. 4Dispose of all components as medical waste.

Routine care

  1. •Flush the catheter every 8–12 hours with 10–20 mL sterile saline (clamp vacuum, flush, then re-establish vacuum).
  2. •Change the dressing daily; inspect the site for leakage, redness or infection.
  3. •Record drainage volume, colour and characteristics each shift; monitor vital signs and pain at the insertion site.
  4. •Maximum recommended duration: 29 days (clinical judgement prevails). Assess every 8 hours.
  5. •If drainage stops, blood appears, or signs of infection or distress occur, notify the physician and consider adjustment or removal.

Summary from the Instructions for Use. Use by qualified personnel according to the full Instructions for Use.

Warnings & Storage

Warnings and precautions

  • Single use only; do not re-sterilize.
  • Maintain strict asepsis.
  • Verify the sterilization indicator (blue means sterile). Do not use if the package is damaged or shows a non-sterile indicator.
  • Discontinue immediately if signs of allergic reaction or infection appear.
  • For use by trained healthcare providers only; improper operation may put patient safety at risk.
  • Use only manufacturer-provided or validated connectors that match the catheter inner diameter; perform a leak test before use.
  • If lubrication is needed, use only a sterile water-soluble lubricant (e.g. medical glycerin); do not use petroleum-based products.

Storage, transport and disposal

  • Shelf life: 3 years from the production date.
  • Storage: cool, ventilated and dry area.
  • Transport: protect against dampness, compression and rain; avoid collisions, friction or scratches with hard objects.
  • After use, the product may be contaminated. Dispose of it as medical waste according to hospital procedures and local regulations.

Packaging

Sterile Single Use Negative Pressure Drainage Set Unit package
Unit package
Sterile Single Use Negative Pressure Drainage Set Middle box
Middle box
Sterile Single Use Negative Pressure Drainage Set Outer carton
Outer carton
LevelDescriptionQuantityDimensions
Unit packagePaper / clear film pouch holding the complete set, with product label1 set—
Middle boxPrinted box——
Outer cartonCorrugated carton48 sets450 × 520 × 590 mm
Carton volume0.138 m³

Packaging images are for reference only.

FAQ