Catheter Series

Silicone Foley Catheter Manufacturer for Distributors

Shenyun Medical is a medical device manufacturer in Suzhou, China, with a 4,000 m² production area and a Class 100,000 cleanroom. We manufacture the SY03 100% silicone Foley catheter (2-way and 3-way, 8–30 FR, balloon 3–30 mL; sterile, single use) in our own factory and supply distributors, importers and hospital procurement teams; our products are exported to 50+ countries and regions. Specifications, product documents (datasheet and IFU) and quotations are available on request.

Models
SY03-08 – SY03-30T
Sizes
8–30 FR
Types
2-way / 3-way
Balloon
3–30 mL
Material
100% silicone, latex-free
Supply
Sterile (EO), single use
Foley Catheter (Balloon Urinary Catheter)

Specifications

ModelSize (FR)Balloon Capacity (ml)Type
SY03-088 FR3–5 ml2-way
SY03-1010 FR3–5 ml2-way
SY03-1212 FR3–5 ml2-way
SY03-1414 FR5–10 ml2-way
SY03-1616 FR5–10 ml2-way
SY03-1818 FR5–10 ml2-way
SY03-2020 FR5–10 ml2-way
SY03-2222 FR5–10 ml2-way
SY03-2424 FR5–10 ml2-way
SY03-2626 FR30 ml2-way
SY03-18T18 FR5–10 ml3-way
SY03-20T20 FR5–10 ml3-way
SY03-22T22 FR5–10 ml3-way
SY03-24T24 FR5–10 ml3-way
SY03-26T26 FR30 ml3-way
SY03-30T30 FR30 ml3-way

Product Information

Foley catheter (balloon urinary catheter) made of 100% silicone, latex-free and uncoated, for transurethral indwelling drainage of urine; the retention balloon is inflated with sterile water to hold the catheter in the bladder. 2-way (8–26 FR) and 3-way with irrigation lumen (18–30 FR); supplied sterile (EO) for single use.
Foley Catheter (Balloon Urinary Catheter)

Structure & Components

1

2-way Foley

catheter shaft with drainage lumen and inflation lumen, retention balloon, drainage funnel and inflation valve.

2

3-way Foley

as 2-way, with an additional irrigation lumen and irrigation port.

3

Nelaton

straight catheter with drainage eyes and funnel, without balloon.

Features

100% silicone, latex-free, uncoated

Retention balloon holds the catheter in the bladder

Transparent tubing for visual monitoring of urine color and characteristics

8–30 FR, 2-way and 3-way types

Indications & Contraindications

Indications

  • Foley catheters are intended for transurethral drainage of urine from the bladder; the retention balloon holds the catheter in place for indwelling drainage.
  • 3-way Foley catheters are additionally intended for bladder irrigation.
  • Nelaton catheters are intended for intermittent transurethral bladder drainage.
  • Patients requiring bladder drainage, selected by the physician; paediatric sizes and lengths are available.
  • Intended user: healthcare professionals trained in urethral catheterisation.
  • Intended environment: hospitals and other healthcare facilities.

Contraindications

  • Known or suspected urethral injury, for example after pelvic trauma or with blood at the urethral meatus.
  • Urethral stricture or obstruction that prevents passage of the catheter.
  • Acute urethritis, prostatitis or epididymitis.
  • Known allergy to silicone.

How to Use

Foley catheter

  1. 1Select the catheter size and balloon volume. Check the package and expiry date, and prepare a sterile field.
  2. 2Clean the urethral meatus according to hospital protocol.
  3. 3Lubricate the catheter tip with a water-soluble lubricant and insert it gently into the urethra.
  4. 4Advance until urine flows, then advance a further 2–3 cm to make sure the balloon is in the bladder.
  5. 5Connect a needle-free syringe with sterile water to the inflation valve and inflate the balloon with the volume marked on the catheter.
  6. 6Pull back gently until resistance is felt, then connect the catheter to a closed drainage system and secure it.
  7. 7For 3-way catheters, connect the irrigation line to the irrigation port.
  8. 8To remove, attach a syringe to the valve, allow the balloon to deflate completely, then withdraw the catheter gently.

Nelaton catheter

  1. 1Select the catheter size, check the package and expiry date, and prepare a sterile field.
  2. 2Clean the urethral meatus according to hospital protocol.
  3. 3Lubricate the catheter tip with a water-soluble lubricant and insert it gently into the urethra until urine flows.
  4. 4Drain the bladder into a suitable container, then withdraw the catheter slowly and dispose of it.

Summary from the Instructions for Use. Use by qualified personnel according to the full Instructions for Use.

Warnings & Storage

Warnings and precautions

  • Inflate the balloon with sterile water only, after urine flow confirms that the balloon is in the bladder. Do not use saline or air, and do not exceed the balloon volume marked on the catheter.
  • Use aseptic technique. Do not use if the package is opened or damaged, or after the expiry date.
  • Do not test-inflate the balloon before insertion.
  • Do not use a syringe with a needle to inflate the balloon, and do not puncture the catheter shaft.
  • Use only a water-soluble lubricant.
  • Never force the catheter; if resistance is felt, stop and consult a physician.
  • Deflate the balloon completely before removal; let the water return into the syringe slowly and do not cut the catheter.
  • Single use only. Do not re-sterilize or reuse.
  • Duration of indwelling and replacement intervals are determined by the physician according to clinical practice.

Storage, transport and disposal

  • Store in the original packaging in a cool, dry place away from direct sunlight.
  • After use, the product may be contaminated. Dispose of it as medical waste according to hospital procedures and local regulations.

Packaging

LevelDescriptionQuantityDimensions
Unit packagePaper / clear film pouch with product label1 pc—
Middle boxBox——
Outer cartonCorrugated carton—56 × 56 × 45 cm
Carton volume0.141 m³

FAQ